Product Item: 350kW 438kVA Diesel Generator Set
Fuel Type: Diesel
Engine: Cummins KTA19-G2
Alternator: Stamford UCI444E
Controller: Deepsea DSE7320
Prime Power: 350kW, 438kVA
Standby Power: 400kW, 500kVA
Power Factor: 0.8
Frequency: 60 Hz
Rated Speed: 1800 RPM
Output Voltage: 240 V
Rated Current: 601 Amps
Oil Consumption: 0.415 L/H
Dimension: 3315 * 1100 * 1650 mm
Weight: 3750 kg
Engine Specifications
|
Engine Brand |
Cummins |
|
Engine Model |
KTA19-G2 |
|
No. of Cylinders |
6 Cylinders (Inline) |
|
Bore × Stroke |
159 mm × 159 mm |
|
Displacement |
18.9 L |
|
Cooling Fan Air Flow |
588 m³/min |
|
Compressed Air Flow |
34.7 m³/min |
|
Exhaust Gas Flow |
96.2 m³/min |
|
Exhaust Gas Temperature |
557°C |
|
Lubrication Oil Capacity |
50 L |
|
Cooling Water Capacity |
91 L |
|
Starting Voltage |
24 V |
|
Engine Max. Output Power |
448 kW |
Alternator Specifications
|
Brand |
Stamford |
|
Alternator Model |
UCI444E |
|
Rated Output |
440kVA |
|
Frequency |
60 Hz |
|
Altitude |
≤ 1000 m |
|
Insulation Class |
H |
|
Protection Grade |
IP23 |
|
Optional Alternator Brands |
Leroy Somer, Marathon, Mecc Alte, Chinese Brushless Alternator |
Control Panel Functions
|
Automatic Genset Start/Stop |
Automatically starts and stops the generator as needed. |
|
Automatic Battery Charger |
Charges the battery automatically to maintain optimal levels. |
|
Emergency Stop |
Provides immediate shutdown in emergency situations. |
|
AMF (Automatic Mains Fault) |
Detects utility failure and starts the generator automatically. |
|
Remote Control |
Enables remote operation and monitoring of the generator. |
|
Microprocessor-Based Design |
Ensures high reliability and intelligent control. |
|
LED Alarm Indication and Sound Alarm |
Visual and audible alarms for fault notification. |
Diesel Generator Protections
|
Over/Under Speed |
Alarm and shutdown if engine runs outside speed limits. |
|
Start/Stop Failure |
Alarm if engine fails to start or stop properly. |
|
Over Current |
Alarm and shutdown on excessive current draw. |
|
Under/Over Generator Voltage |
Alarm and shutdown on abnormal voltage levels. |
|
Low Oil Pressure |
Alarm and shutdown when oil pressure drops below safe limits. |
|
High Engine Temperature |
Alarm and shutdown to prevent overheating damage. |
|
Over Load |
Alarm and shutdown if load exceeds generator capacity. |
|
Low and High Battery Voltage |
Alarm on abnormal battery voltage. |
|
Loss of Speed Signal |
Alarm and shutdown on failure of speed sensing. |
|
Charge Fail |
Alarm if battery fails to charge properly. |